OEM DGA Sensor — Hydrogen Sensing Elements & Modules for System Integrators

Palladium-alloy dissolved-hydrogen sensing elements and OEM/ODM modules for transformer monitoring manufacturers, condition-monitoring integrators, and private-label suppliers. Register map and integration documentation supplied under NDA.

What this page covers

PAS DGA supplies three OEM forms of the same sensing platform. Which one fits depends on whether you are building your own monitor, reselling a finished sensor, or adding gas analysis to an existing product line.

OEM form Model What you receive Typical buyer
OEM sensing element DGA-300 Palladium-alloy MOSFET hydrogen element with RS-485 / Modbus RTU output Monitor manufacturers embedding hydrogen sensing into their own enclosure and firmware
Standalone OEM sensor DGA-500 Complete valve-mount dissolved-hydrogen sensor with oil temperature Integrators and distributors who want a finished sensor under their own brand
OEM / ODM module DGA-700-OEM Multi-gas sensing core (H₂, CO, moisture; C₂H₂ optional) for system integrators Suppliers building a multi-gas monitor without in-house gas-sensing development
What this is not. These are sensing components and modules, not complete monitoring systems with third-party certification. They are supplied factory-tested and individually calibrated. No third-party type-test, EMC, IP or IEC 61850-10 conformance certificate is claimed. If your project requires type-tested equipment for a utility tender, these products are not the right fit — and we will tell you so before you order.

Typical integration scenarios

1. Building your own online hydrogen monitor

You have the enclosure, power supply, communications stack and a customer base. You need the sensing physics, the calibration and the register map. The DGA-300 element mounts through a 1/2 in. two-ferrule fitting and reports over RS-485; your firmware polls it like any other Modbus slave.

2. Adding a hydrogen channel to an existing product

You already sell a monitoring device — partial discharge, bushings, tap changers — and customers keep asking for dissolved gas. Adding a hydrogen channel is the cheapest credible answer: it detects arcing and partial discharge earlier than most other single parameters, and it does not require gas chromatography, carrier gas or consumables.

3. Private-label supply

You sell under your own brand into a region we do not serve directly. The DGA-500 is the finished-sensor option: our label comes off, yours goes on. Regional exclusivity, minimum volumes and documentation language are set per agreement — see OEM & distribution partnerships.

4. Replacing sensors on equipment already in service

Existing hydrogen sensors reach end of life or lose calibration. Because the platform carries no degassing membrane and no consumable, replacement is a mechanical swap plus a Modbus re-point, not a re-engineering project.

Measurement specifications

DGA-300 — OEM sensing element

Item Specification
Detection principle Palladium-alloy MOSFET structure
Measuring range 2 – 2 000 ppm H₂ (operation beyond range may damage the chip)
Limit of detection 2 ppm
Accuracy / repeatability ±20 % of reading or ±2 ppm / ±10 % or ±2 ppm (whichever is greater)
Resolution 1 ppm
Response time T90 < 10 min (oil hydrogen above 50 ppm)
Applicable oil temperature 0 ~ +60 °C
Ingress protection / weight / length IP67 / 350 g / 186 mm
Process connection 1/2 in. two-ferrule tube fitting
Power / output 24 V DC, 0.3 A · RS-485 Modbus RTU

DGA-500 — standalone OEM sensor

Item Specification
Detection principle Palladium-alloy thin-film resistor element, chip immersed directly in oil
Measuring range 5 – 5 000 ppm H₂ (operation beyond range may cause irreversible damage)
Limit of detection 5 ppm
Accuracy / repeatability ±15 % of reading or ±5 ppm / ±5 % or ±5 ppm (whichever is greater)
Resolution 1 ppm
Response time T90 < 30 min (oil hydrogen above 100 ppm)
Applicable oil temperature −40 ~ +105 °C; oil temperature measurement −40 ~ +120 °C, ±1 °C
Moisture (optional) 0 – 100 %RS; ±2 %RS at 0–90 %RS, ±3 %RS at 90–100 %RS; T90 < 10 min
Oil pressure (optional) 0 – 1 MPa, ±1 % F.S., 0.1 kPa resolution, 3 MPa overload
Power / output 24 V DC ±10 %, 0.3 A max · RS-485 Modbus RTU
Ingress protection / weight IP67 / 500 g
Data storage 30 s interval, 74 604 entries
Process connection 1/2 in. two-ferrule tube fitting; 241.5 mm overall length, Ø12.7 mm probe rod

DGA-700-OEM — multi-gas module

Channel Range Measurement error limit
Hydrogen H₂ 0 – 2 000 µL/L ±3 µL/L or ±30 %
Carbon monoxide CO 0 – 3 000 µL/L ±30 µL/L or ±30 %
Moisture H₂O 0 – 100 µL/L ±3 µL/L or ±10 %
Acetylene C₂H₂ (optional) 0 – 2 000 µL/L ±1 µL/L or ±30 %

Module supply 220 V AC ±10 % / <200 W; ambient −40 ~ +55 °C; 10 – 95 % RH; measurement cycle configurable from 10 minutes to 24 hours; RJ45, fibre optic and RS-485; IEC 61850, Modbus and TCP/IP.

Integration interface

All three forms speak Modbus RTU over RS-485 as a standard hardware half-duplex slave. Default 19200 bps, N/8/1, function codes 0x03 (read holding registers) and 0x06 (write single register), host timeout 10 seconds or more.

Available data includes instantaneous, average and hourly-average values, daily / weekly / monthly rate of change, oil temperature, PCB temperature, device status bits, relay status, model and serial number.

A serial command interface over RS-232 exposes device information, calibration (DA / DB / DX), time setting, initialisation and log retrieval. The full register map and integration document are supplied under NDA — we do not publish it on an open page.

Calibration and field service

Every element is individually calibrated before shipment; that is the baseline reference. In service, hydrogen is validated against an oil sample taken near the sensor and analysed off-line by gas chromatography to ASTM D3612. If the reading deviates by more than 15 %, the sensor is corrected to the laboratory value with the DB command. DX clears the stored calibration and restores factory state.

Because the element sits directly in the oil with no degassing membrane, no carrier gas and no sensor replacement schedule, there is no periodic maintenance item to price into your service contract.

MOQ, lead time and documentation

  • MOQ and price — quoted per configuration and annual volume bracket. We do not publish a price list, because the element, housing, cable length and moisture / pressure options change the cost materially.
  • Lead time — confirmed at quotation, against the specific configuration. Sample quantities and production quantities are quoted separately.
  • Documentation — datasheet, register map, integration guide, factory inspection report and certificate of conformity. Additional documentation is available under NDA.
  • Warranty — 24 months from shipment on DGA-300 / DGA-500, extendable by agreement.
  • Branding — private label supported for the DGA-500 and DGA-700-OEM; the element itself carries no visible brand.

What we do not claim

  • No third-party type-test, EMC, ingress-protection or IEC 61850-10 conformance certificate.
  • No statements about utility tender eligibility — type-tested equipment is a different supply category.
  • No cross-interference figures beyond what the datasheet states, because we do not have measured data for every gas pair.
  • No lifetime in years for the sensing element or any optical component.

Frequently asked questions

Can I integrate the element without buying a complete monitor?

Yes. The DGA-300 is supplied as a sensing element with RS-485 output. You provide the enclosure, power and firmware. A register map and integration guide are supplied under NDA.

Do I need carrier gas or a degassing membrane?

No. The element is immersed directly in the oil. There is no carrier gas, no membrane and no consumable to replace.

Can the sensor be installed on a transformer that is already energised?

Yes, at the main-tank ball valve or the bushing oil sampling port. The valve stays closed until the adapter is fitted; a 1/2 in. ferrule-to-flange adapter is required. Detailed procedure is in the product manual.

What is the difference between the DGA-300 and the DGA-500?

The DGA-300 is a MOSFET-structure element with a 2 ppm detection limit and a 0 – 60 °C oil temperature window — it is designed to be embedded. The DGA-500 is a thin-film resistor element in a finished IP67 sensor with a −40 ~ +105 °C window and optional moisture and oil pressure channels — it is designed to be installed and sold as a sensor.

Do you private label?

Yes, for the DGA-500 and the DGA-700-OEM. Regional exclusivity and minimum volumes are set per agreement.

Request OEM pricing and the integration document

Tell us the model, the quantity bracket and your enclosure or firmware constraints. We reply with a configuration, a price and the register map.